Calibration for Lorca and Piura

Cydiance Lorca and Piura temperature data loggers are equipped with high accuracy and stable digital temperature/humidity sensors.

We confirm that all sensors used, are manufacturerd by Sensiron from the Switzerland. Sensiron processes the calibration on each unit which traces back to National Institute of Standards and Technology(NIST) from USA, Physikalisch-Technische Bundesanstalt (PTB) from Germany and National Physical Laboratory (NPL) from UK.

Each device is individually tested after its calibration.

You may find a calibration statement from Sensiron as attached from below link, which applies to all sensors supplied to Cydiance.

Calibration Certification Statement from Sensiron

Calibration for C1 & Bee

Cydiance C1 and Cydiance Bee temperature data loggers are equipped with high accuracy and stable digital temperature sensors.

We confirm that all sensors used, are manufacturerd by Texus Instruments(TI) from the United States.TI processes the calibration on each unit which traces back to National Institute of Standards and Technology(NIST) from USA .

You may find a calibration statement from TI as attached from below link, which applies to all sensors supplied to Cydiance.

Calibration Certification Statement from TI

User Manual – B Series

User Manual - B Series

Bee-user-manual-guide.png

WARNING! DO NOT REMOVE the water-proof bag before or in use.

Config (optional)

You may use a mobile App—Cydiance Hive to configure and manage the logger. Download by scanning the QR code underneath with your phone.
Ignore this step if you want to use default setting.

Start

Press the button for 5 seconds till both LED light up, the LED will then flash every 3 seconds indicating the logger is working.

You may also start the device via App.

make a mark

Press the button once, the RUN LED will light up for 1 second, indicating a MARK has been made successfully. Total 8 MARKs can be made.

stop

Press the button for 5 seconds till both LED light up, the RUN LED will then light up all time indicating the logger is stopped and has been used.

Directly plug the USB into computer will stop the logger automatically too.

get the report

A, plug the usb into computer to get an encrypted PDF report;

B, use Cydiance Hive to upload all data to Cydiance Book and log in to check with more features;

C, use Cydiance Hive to send report via email.

User Manual – C1

User Manual - C1 & LiteMP

WARNING!  Do not remove the plastic bag unless you have finished the trip or seen the Run(blue) LED solid.

Start

Press the button for 5 seconds till both LED light up, the LED will then flash every 3 seconds indicating the logger is working.

make a mark

Press the button once, the RUN LED will light up for 1 second, indicating a MARK has been made successfully. Total 8 MARKs can be made.

stop

Press the button for 5 seconds till both LED light up, the RUN LED will then light up all time indicating the logger is stopped and has been used.

Directly plug the USB into computer will stop the logger automatically too.

get the report

Plug USB into computer.

A, if the device has been stopped manually, a flash disk will pop up immediately with an encrypted PDF report;

B, if the device is stopped by USB, you might have to wait a while till the RUN LED become solid, and then a flash disk will pop up with an encrypted PDF report;